1599 – PRM-35 and PRM-32 LED Error Code Messages

1599 – PRM-35 and PRM-32 LED Error Code Messages

Applicable to:

  • PRM 32

    PRM 32

  • PRM 35

    PRM 35

Error Code MessagesTemp LEDPower LEDLamp LED
Ready to Power on (Standby)OffOnOff
System Power onOffBlinksOff
CoolingOffBlinksOff
Over temperatureOnOffOff
Thermal break sensor errorOff4 blinksOff
Lamp errorOffOffOn
Fan 1 errorOff6 blinks1 blink
Fan 2 errorOff6 blinks2 blinks
Fan 3 errorOff6 blinks3 blinks
Lamp door openOff7 blinksOff
DMD errorOff8 blinksOff
Color wheel errorOff9 blinksOff

In the event of an error, please disconnect the AC power cord and wait for one minute before restarting the projector. If the POWER or LAMP LEDs are still blinking or the TEMP LED is lit, contact Promethean Technical Customer Support.

    • Related Articles

    • 1598 – PRM-45 LED Error Code Messages

      Applicable to: PRM 45 A Error Code Messages Power LED Lamp LED Temp LED System initial Flash Off Off Ready to power on (Standby) On Off Off System power on Flash Off Off Lamp lit, system stable On Off Off Cooling Flashing Off Off Over temperature Off ...
    • 1602 – PRM-25 LED Error Code Messages

      Applicable to: PRM 25 Error Code Messages Power LED Ready LED Over temperature 3 blinks Off G794 fail 4 blinks 4 blinks T1 fail 4 blinks 5 blinks Lamp error 5 blinks Off Ballast over temperature 5 blinks 1 blink Ballast short circuit in output ...
    • 1600 – UST LED Error Code Messages

      Applicable to: UST P1 UST P2 Error Code Messages Temp LED Lamp LED Power LED Power On Off Off Green Power Off Off Off Green Cooling Off Off Flashing Over temperature On Off Off Thermal break sensor error Off Off 4 blinks Lamp error Off On Off Fan 1 ...
    • 1601 – EST-P1 LED Error Code Messages

      Applicable to: EST P1 Error Code Messages Warning LED Lamp LED Power LED Power on Off Off Blue Power off Off Off Orange Lamp fail Off On Off Cooling Off Off Flashing Over temperature On Off Off T1 error Off 1 blink 3 blinks T2 error Off 2 blinks 3 ...
    • 1436 – PRM-25 RS232 control code commands

      Applicable to: PRM 25 The commands below should only be used by users who are familiar with using this method of operation. Promethean’s support is limited to the commands outlined below. RS232 Setting Minimum delay for next command: 1ms Control ...